Go to main content

The removal of cadmium ions (Cd2) was evaluated from an aqueous solution on White Cancun and Red Tezontle quarry, using a fraction 2000 m, at 23 °C under dynamic conditions in a packed bed. The percentage of cadmium extraction was studied through adsorption kinetics, and with this the total adsorption capacity and the shelf life of the sorption column were calculated. A volumetric flow rate of 0.3 ml s1 and an initial concentration of 861.75 mg L1 were used, and an initial concentration of 83.2 mg L1, at pH of 7.5. The White Cancun quarry reports a maximum extraction percentage (% E) of 99.59 at the first minute of contact, compared to the tezontle that reports %E83.78 at the same time. However, the total adsorption capacity was 3.60 mg and 6.62 mg, respectively. The period of service life of the column suggests using tezontle as adsorbent.

Metric
From
To
Interval
Export
Download Full History